Belt pulley and misalignment settings with laser

One of the most common source of vibration equipment, electric motor and the driven equipment uniaxial of inaccuracy. This can help to eliminate the source of the error laser misalignment test.

laser sensors to collect information on the details of the coaxial device and after a multi-dimensional evaluation, if required in the machine and check the units immediately set.

During the intervention of the fly laser sensors remain in place, so the test quickly and accurately as possible can be performed. Consider several interconnected unit at a time is possible.

The misalignment settings performed FAG Top Laser Inline-type device that can be used between 12 to 500 mm in diameter axle setup.

The plane of the pulleys to adjust SKF instrument used.